EM13.4: Schedule Jobs Are Not Running Due To Incorrect URL For oracle.sysman.core.pbs.dataloader.connectDescriptor
(Doc ID 2902860.1)
Last updated on DECEMBER 10, 2022
Applies to:
Enterprise Manager Base Platform - Version 13.1.0.0.0 and laterInformation in this document applies to any platform.
Symptoms
All EM scheduled jobs are not running and oms logs report error below:
2022-10-07 04:22:57,095 [GCLoader[severity] - https://oms-hostname:1840/emd/main/] WARN gcloader.DataLoader logp.251 - Connection could not be established using the connect descriptor (DESCRIPTION=(ADDRESS_LIST=(ADDRESS=(PROTOCOL=TCP)(HOST=DB-host)(PORT=6235)))(CONNECT_DATA=(SERVICE_NAME=servicename-loaderjob))) for data loader. Please validate the value oracle.sysman.core.pbs.dataloader.connectDescriptor. Attempting connection using the system pool...
java.sql.SQLRecoverableException: Listener refused the connection with the following error:
ORA-12514, TNS:listener does not currently know of service requested in connect descriptor
java.sql.SQLRecoverableException: Listener refused the connection with the following error:
ORA-12514, TNS:listener does not currently know of service requested in connect descriptor
Cause
To view full details, sign in with your My Oracle Support account. |
|
Don't have a My Oracle Support account? Click to get started! |
In this Document
Symptoms |
Cause |
Solution |