OBIEE 11g: Gauge Pointer Does Not Point to the Correct Percentage Data Value (Doc ID 1338228.1)

Last updated on FEBRUARY 29, 2012

Applies to:

Business Intelligence Suite Enterprise Edition - Version: 11.1.1.5.0 [1308] to 11.1.1.5.0 [1308] - Release: 11g to 11g
Business Intelligence Server Enterprise Edition - Version: 11.1.1.5.0 [1308] to 11.1.1.5.0 [1308]   [Release: 11g to 11g]
Information in this document applies to any platform.

Symptoms

Your analysis comprises 2 columns, one of which is a percentage.  The results are displayed in a table view and a gauge view (Dial).

In the Table view, the "% of Patients Assessed" values are all over 90%.  But in the gauge view, the pointer in all of the gauges is located in the 0% - 33% range.