Exalytics: Running "Summary Advisor" In Administration Tool Fails With 'Check Database Specific Features Table. Must Be Able To Push At Least A Single Table Reference To A Remote Database' (Doc ID 1663518.1)

Last updated on OCTOBER 13, 2016

Applies to:

Oracle Exalytics Software - Version 1.0.0.0.0 and later
Exalytics In-Memory Machine X3-4 - Version All Versions and later
Exalytics In-Memory Machine X2-4 - Version All Versions and later
Business Intelligence Server Administrator - Version 11.1.1.6.2 and later
Business Intelligence Suite Enterprise Edition - Version 11.1.1.6.2 and later
Information in this document applies to any platform.

Symptoms

You have intergrated Times Ten 11.2.2.4.5 with OBIEE 11.1.1.6.2. However, while executing "Summary Advisor" it fails with the below error:

[NQODBC] [SQL_STATE: HY000] [nQSError: 10058] A general error has occurred.
[nQSError: 43113] Message returned from OBIS.
[nQSError: 43119] Query Failed:
[nQSError: 42016] Check database specific features table. Must be able to push at least a single table reference to a remote database
[nQSError: 98009]Execution of Summary statistics data retrieval query failed:

 

 

Cause

Sign In with your My Oracle Support account

Don't have a My Oracle Support account? Click to get started

My Oracle Support provides customers with access to over a
Million Knowledge Articles and hundreds of Community platforms