OBIEE 11g Cannot Upgrade The RPD Or Web Catalog - Error Indicates Found 2 Instances (Doc ID 1681635.1)

Last updated on NOVEMBER 03, 2015

Applies to:

Business Intelligence Server Enterprise Edition - Version 11.1.1.6.0 and later
Business Intelligence Suite Enterprise Edition - Version 11.1.1.6.0 and later
Information in this document applies to any platform.
Updated the topology.xml file by removing the OHS instance and restarting, but this did not solve the problem.

Symptoms

Error
=====
[2014-05-19T11:40:10.465-04:00] [Framework] [ERROR] [] [upgrade.Framework] [tid: 13] [ecid: 0000KOL8xoqAPPp5SR^Ayc1JUYMB000004,0] UPGCMP-02712: Expected oracle.biee.admin:oracleInstance=*,type=BIDomain.OracleInstance,group=Service Oracle instance, found 2

 

Another problem resolved by this is seeing the following error when using the OBIEE 10g to 11g upgrade assistant:

Error
=====
UPGCMP-02712: Expected oracle.biee.local:* Oracle instance, found 0.

Changes

 None.  Just upgrading.

Cause

Sign In with your My Oracle Support account