FDMEE Doesn't Reset the Weblogic Active Connection for (aif-source) to 0 After Completing Any Data Load. (Doc ID 1996556.1)

Last updated on AUGUST 01, 2016

Applies to:

Hyperion Financial Data Quality Management, Enterprise Edition - Version 11.1.2.3.000 to 11.1.2.3.520 [Release 11.1]
Information in this document applies to any platform.

Symptoms

After performing data load process in FDMEE , the weblogic active connection for (aif-source) does not reset to a lower value or 0.

This results in error message "No resources currently available in pool aif_datasource".

Example:

Data needs to be loaded into Essbase from FDMEE.

Number of files : 500.

After 150 files loaded, user get the error message "No resources currently available in pool aif_datasource".

After increasing the connection pool for jdbc source (aif-source) in WebLogic from default to 700 , it load fine.

If users load 500 files again , they get the same error .

This is because the process will begin at the 501st connection, and will fail when it will reach 700. The Active Connections is not reset to 0 after the FDMEE loading is completed.

Cause