Goal

When using a read-only user to run an ODI data load from EBS. The data load failed with the following error:

ODI-1227: Task SrcSet0 (Loading) fails on the source ORACLE connection R12VIS.
Caused By: java.sql.SQLSyntaxErrorException: ORA-00904: "INV_CONVERT"."INV_UM_CONVERT_NEW": invalid identifier


<Note 1614683.1> ETL Full Load Failing With Error ORA-00904: “INV_CONVERT”.”INV_UM_CONVERT_NEW’: Invalid Identifier -  explains that the INV_CONVERT.INV_UM_CONVERT_NEW is a PLSQL procedure that is present in EBS, and the ETL user must have access to this procedure and also has EXECUTE privileges granted. However, even after granting the user execute access to the package, still get the same error. 
 