OBIEE 12c: OBIPS : Presentation Service Does Not Start After Rebooting The Windows 2012 Server.
(Doc ID 2289533.1)
Last updated on MAY 05, 2023
Applies to:
Business Intelligence Suite Enterprise Edition - Version 12.2.1.0.0 and laterInformation in this document applies to any platform.
Symptoms
Oracle Business Intelligence Enterprise Edition 12c
- Rebooted Windows 2012 server where BI is running.
- Post that Presentation Service does not start.
AdminServer.out shows the following error details:-
<Notice> <Server> <BEA-002613> <Channel "Default" is now listening on xx.xx.xx.xx:9500 for protocols iiop, t3, ldap, snmp, http.>
<Notice> <Server> <BEA-002613> <Channel "Default[2]" is now listening on 0:0:0:0:0:0:0:1:9500 for protocols iiop, t3, ldap, snmp, http.>
<Notice> <WebLogicServer> <BEA-000360> <The server started in RUNNING mode.>
<Notice> <WebLogicServer> <BEA-000365> <Server state changed to RUNNING.>
After load: Instance: obips1
OBIPS -> OBIPS.obips1 tcp(s)://unknownhost.example.com:9507(9507)/ - System Component
.............
<Error> <NodeManager> <BEA-300048> <Unable to start the server obips1: Received error message from Node Manager Server: [Server start command for OBIPS server 'obips1' failed due to: [Server failed to start up but Node Manager was not aware of the reason]. Please check Node Manager log and/or server 'obips1' log for detailed information.]. Please check Node Manager log for details.>
Changes
Did a Server Reboot
Cause