My Oracle Support Banner

E1: 13: P12120 Meter Readings does not show correct Meter Reading from a Past Period (Doc ID 1626343.1)

Last updated on NOVEMBER 17, 2016

Applies to:

JD Edwards EnterpriseOne Capital Asset Management - Version 9.1 to 9.1 [Release 9.1]
Information in this document applies to any platform.

Symptoms

P12120 - Meter Readings - is not showing the correct Meter Reading in the following Use Case:

1. P12120 inquiry is on an Equipment and its Responsible Business Unit.
2. An inquiry if first done with a Thru Date in one period and then (without exiting the applciation) another inquiry is done with a Thru Date in a prior period.

STEPS TO REPRODUCE
==================
1. Create an Asset with Responsible BU = M30.
2.Enter a variety of Meter Readings over Fiscal Period 9, 10 and 11 (Sept to Nov).

G/L Date Units Cumulative
02/09/13 150 150
20/09/13 70 220
27/09/13 40 260
30/09/13 26 286
04/10/13 19 305
14/10/13 74 379
21/10/13 31 410
24/10/13 27 437
29/10/13 30 467
31/10/13 26 493
01/11/13 9 502
15/11/13 106 608
 
3.Go to P12120 Meter Readings and inquire on your Equipment, Resp BU = M30 and Thru Date = 15th Sept. Note that the Meter Reading is 150. This is correct.
4.Exit P12120.
5.Go back into P12120.
6.Inquire on your Equipment, Resp BU = M30 and Thru Date = 15th Oct. Meter Reading is 379. Correct.
7.Change Thru Date to 15th Sept and click [Find]. Note Meter Reading is 286. This is incorrect and relates to the Meter Reading as of 30th Sept.


Cause

To view full details, sign in with your My Oracle Support account.

Don't have a My Oracle Support account? Click to get started!


My Oracle Support provides customers with access to over a million knowledge articles and a vibrant support community of peers and Oracle experts.