E1: 31: R31122Z1I Does not Reset F31122Z1.EDSP Flag to Y (Doc ID 1633098.1)

Last updated on DECEMBER 24, 2015

Applies to:

JD Edwards EnterpriseOne Shop Floor Control - Version 9.1 to 9.1 [Release 9.1]
Information in this document applies to any platform.

Symptoms

P31122Z1 - Work Order Time Transactions Unedited Transaction Table
R31122Z1I - Hours and Quantities Inbound Processor

R31122Z1I is run for processing records on the F31122Z1 table. Some records are not successfully processed because the work order status is bigger than the status allowed for changes (P.O. # 1. ‘Enter the Status Code from which Shop Floor Activity cannot be entered’ in the P311221 version called by R31122Z1i) and those lines are marked correctly with the flag EDSP=N.
The WO status is then reset to a status allowed for changes but the EDSP flag is still set to ‚N' for those WOs.
If re-running R31122Z1I over those records with the flag EDSP already set to N, the UBE finishes correctly, does not display any error messages on the pdf output, the F31122 table is updated with the corresponding records but the EDSP flag (Successfully Processed) is not updated to ‚Y’.
Every time the batch runs, a new line is added to F31122 because the EDSP = N is not update to Y, even if the F31122Z1 record is correctly processed and added in F31122.

Cause