Symptoms

E1 9.1 Blend Management
P31B94 / P31B87 Enter/Change Blend Operation

Error 'Material Type UOM Invalid' (error id 207WIM) is generated when combining (T2T) tank volumes if, on the configured operation, a Valid Material Type
record exists. (P31B75P, Action 'Material Types' - form W31B75PG).  It does not matter if the Valid Material Type flag (MTVAL) is 'I' (Invalid) or 'V' (Valid).
 
ERROR
-----------------------
Material Type UOM Invalid  
Cause : The UOM of the Material Type does not match the UOM specified in Configurator.
Resolution : Enter the valid UOM.
ER Details:
    Form   P31B67F_S31B67FA
    Control Id   20
    Line No   63
BSFN Details:
    Source File   b31b1190.c
    Source Line   2870
    Error ID   207WIM
    BSFN DSTR Item   49

Cause