Symptoms

Application Release: 9.1
Program impacted: RF31210

RF31210 in final mode & summarized on more than 50 transactions per work center will run indefinitely. Job needs to be terminated

The issue can be reproduced at will with the following steps:

For 450 or so transactions:

1. Run RF31210 in Summary and Proof mode over PD. It runs in a few minutes
2. Run RF31210 in Summary and Final mode over PD. It never stops. We have to terminate the job, and VF in F31011 remains at a 2.
3. Run RF31210 in Summary and Proof mode over PY. It runs in a few minutes.
4. Run RF31210 in Summary and Final mode over PY and select less than 40 records at a time, and it runs in a few minutes. We continued to run RF31210 grabbing only 40 or less records at a time, and we eventually processed all 450 records.
5. Run RF31210 in Summary and Final mode over PY with all the records, and we have to terminate the job.
6. Run RF31210 in Detail and Final mode over PY with all the records, and it runs in a few minutes.




Cause