E1: SEC: Action Security On P3404 Application Not Applied If CO/By Product Is Not Setup

(Doc ID 1968012.1)

Last updated on MAY 30, 2017

Applies to:

JD Edwards EnterpriseOne Tools - Version 9.1 to 9.1 [Release 9.1]
Information in this document applies to any platform.

Symptoms

Action Security (set with only OK/Select set to Y and the other options set to N) on P3404 -CO/By Products Planning Table  application is ignored when the CO/By product hasn't been set up in P3404 for a certain process item (no record in table F3404).
This appears in Form W3404N that is being called from W3404M(initial form of P3404) after pressing the select button.

STEPS TO REPRODUCE
==================
1. Make sure you have a CO Product that hasn't been set up in P3404


2. Set Action security with all values N, except OK/SELECT that is set to Y


3. Test with a user that has the security


4. Notice that when you open the CO Product that doesn't have a record in F3404, the OK button in form W3404N appears.


This doesn't happen for the other CO Products that have records in F3404.

Cause