E1: 13: P17714 Not Updating Status Change Date Field DCG In F4801 (Doc ID 1984057.1)

Last updated on DECEMBER 10, 2015

Applies to:

JD Edwards EnterpriseOne Capital Asset Management - Version 8.12 to 9.1 [Release 8.12 to 9.1]
Information in this document applies to any platform.

Symptoms

When creating a Work Order in Equipment Work Order Entry P17714, or when changing the work order status using field SRST in the Planning Tab of the WO to a next allowable status no error is given, and the Work Order Status Change Window pops as expected.

However after clinking OK it is noticed that the F4801 Work Order file, field DCG Status Change Date is Blank / not updated.

Note: The status is changed in the F4801 SRST Work Order Status field as expected



Steps To Duplicate
-----------------------
1. Go to Menu G1316 / P48201 Inquire on the WO in question and select it to go to / P17714 Equipment WO Entry
2. In the Planning Tab of the P17714 change the WO Status to the Next allowable status click Ok to go to the Work Order Status Change Window and click OK again to save change.
3. Data Browse the F4801 Work Order file and inquirer on the work order number.  Notice the Status has changed as expected in the SRST WO Status field, however the "Date Changed has not update in the DCG Status Change Date field.