E1: 41: Cycle Count Update R41413 Updates F41021T Wrongly (Doc ID 2126986.1)

Last updated on MARCH 08, 2017

Applies to:

JD Edwards EnterpriseOne Inventory Management - Version 9.1 and later
Information in this document applies to any platform.

Symptoms

Run R41411 (Select items for count). On hand quantity of an item with
production number is 1EA. It is shipped and its on hand is relieved. So on
hand quantity becomes zero. Next, enter counted quantity (P41240). At this
moment, enter 1EA as counted quantity for the item. Then run R41413 (Update
count). F41021 is updated to zero correctly. However, F41021T is updated wrongly. On
hand quantity of the item becomes 1EA back instead of zero.

Cause