E1: 46L: R46171 System Suggests the Overflow Location when Capacity Method is Set as 3 (Doc ID 2160446.1)

Last updated on JULY 25, 2016

Applies to:

JD Edwards EnterpriseOne Warehouse Management - Version 9.0 and later
Information in this document applies to any platform.

Symptoms

On : 9.0 version, License Plating
R46171 Location Selection Driver

When attempting to perform putaway suggestion for capacity method 3 in LP environment, the following error occurs

ERROR
-----------------------
Error 3223[ Location full for item/UOM].

STEPS
-----------------------
1.Create the items AL and AL1 having the item structure defined as PL-CA-EA.
2.Both the items are linked to the license plate b/p LIC and warehouse process group AMH.
3.In P46011, item AL is setup for capacity method 1[Volume Checking] and item AL1 is linked to capacity method 3[Quantity Checking].
4.P46024 is setup for item AL1 accordingly.
5.F46L30 shows that there is enough space available at locations 1.A.1 and 1.A.2
6.P46093 and P46095 have been setup as well.
7.1.A.1 and 1.A.2 are used as the fixed putaway locations for items AL and AL1 respectively.
8.Create a PO for item AL for 20 EA.
9.Receive the order using P4312 with the processing option turned on for license plating
10.Run the R46171 and notice that location 1.A.1 is suggested correctly for the item.
11.Create the next PO for 20 EA for item AL1.
12.Receive the second order using P4312 with license plating enabled.
13.Run the R46171 and notice that system suggests the Overflow location which is incorrect. It throws the error 3223[ Location full for item/UOM].


Cause

Sign In with your My Oracle Support account

Don't have a My Oracle Support account? Click to get started

My Oracle Support provides customers with access to over a
Million Knowledge Articles and hundreds of Community platforms