E1: IOT: Multiple Sessions Not Closed When Testing AIS Orchestration Request with Incorrect Data (Doc ID 2219400.1)

Last updated on MAY 30, 2017

Applies to:

JD Edwards EnterpriseOne Tools - Version 9.1 and later
Information in this document applies to any platform.

Symptoms

While testing delivered orchestration samples with incorrect data it throws an error on the SoapUI as expected, But however it is not closing the opened session on AIS server. And if we post same request multiple times from single opened session this opens multiple sessions on AIS server and it will not close them. Due to this issue AIS server is getting overloaded with more number of connections opened.

Steps to Reproduce the Issue:

1) From SoapUI Test JDE_ORCH_Sample_UpdateEquipmentLocation Orchestration by entering an invalid device it will error our as expected with message " This asset number does not exist in the Item Master file (F1201)". 

2) Now try to post the same message for 8 time from same request you could see 8 new sessions opened on AIS server and all unsuccessful transactions(8 sessions) will not get closed automatically after returning the error message to SOAPUI.

Changes

 

Cause

Sign In with your My Oracle Support account