E1: 32: Manually Changed Line Type Reverts Back to Default in P3293 (Doc ID 2232249.1)

Last updated on JULY 25, 2017

Applies to:

JD Edwards EnterpriseOne Configurator - Version 9.1 and later
Information in this document applies to any platform.

Symptoms

When adding a new P rule in the P3293, the line type will default from the Item Branch (F4102) if using a named branch plant or from the Item Master (F4101) if using generic (blank) branch plant. If the user overrides the line type (i.e. from W to S) and clicks save, the system will maintain the change. However, upon re-inquiring on the P rule, the system will change the value back to the line type from the Item Branch/Item Master. Subsequently, if the user clicks on the OK button, the F3293 line type will be inadvertently changed.

Cause