Symptoms

E1 9.2 / Instruct Lot Attributes, P31B94 > P31B31

When the 'area-to-liter' UOM conversion is setup on a spray item's Item UOM Conversion (F41002), error "Unit of Measure Conversion Unsuccessful" (error id 0269) is incorrectly generated in the
Instruct Lot Attributes (P31B31) After Accumulated Additives on a grower SPRAY operation.
If the same 'area to liter' UOM is defined in the Standard UOM Conversion table (F41003), the error is not generated.

If a UOM conversion is setup at the item level (F41002), a Standard UOM Conversion (F41003) should not be required.