My Oracle Support Banner

E1: 46L: No WMS Validation for WO Completion (P31114) Within LPN Branch (Doc ID 2279642.1)

Last updated on FEBRUARY 06, 2019

Applies to:

JD Edwards EnterpriseOne Warehouse Management - Version 9.1 and later
Information in this document applies to any platform.

Symptoms

********************
E1 Release: 9.1
Program ID: P31114
Tools Release: 9.1
***************************

When doing Work order completions in a warehouse with License Plating, if the item is missing item profile information (F46011) or UOM conversion structure codes then the system still processes the WO completions and No Error is shown on screen, even though some errors are sent to the work center. NO Put away request (F4600) is created either.

STEPS
-----------------------
The issue can be reproduced at will with the following steps:
1) Set up MfG with parent and component item in License Plate Branch
2) Set up UOM conversion but leave UM structure code blank
3) P3002 Set up BOM
4) P46011 Set up U/M definition for component item
5) P48013 Enter work order for parent item
6) Run R31410 to attach parts list
7) Set up WO completion (P31114) to create Put away request and to generate LPN and complete work order
8) Note that work order is completed but No Put away request is created
9) An error is issued to the work center - B46L0240 - UOM structure can not be determined


Cause