E1: UBE: RUNUBEXML Jobs on AS/400 Fail with QPJOBLOG Errors Such As "Value 'RX01105290' for FILE exceeds 10 characters"

(Doc ID 2345436.1)

Last updated on JANUARY 04, 2018

Applies to:

JD Edwards EnterpriseOne Tools - Version SP23 and Prior to SP24 [Release SP23 and Prior to SP24]
IBM i on POWER Systems

Symptoms

On OneWorld Xe or ERP8 with a tools release/service pack prior to SP24.1.3, running on the AS/400 platform, reports (UBEs) submitted from a command prompt via the RUNUBEXML command are failing with errors such as this in the operating system QPJOBLOG files:

"Value 'RX01105290' for FILE exceeds 10 characters"

 

Other reports (UBEs) submitted from Batch Versions (BV) are running with no issues.

 

The final XML file generated by the RUNUBEXML command contains a message such as:

'CRTPF Command failed for FILE(B7334SYS/RX011052007) with error message: CPF00010'/></ACTION></jdeResponse>
 

 

Changes

 

Cause