Goal
Why P4112 issues error below?
Error 1: 085D - UOM Conversion EA to MO Unsuccessful
CAUSE . . . . An error condition was encountered when attempting to convert a quantity from unit of measure "EA" to "MO". An error results when a conversion factor to the primary unit of measure cannot be found for one or both of the units of measure involved in the conversion.
RESOLUTION. . Use the Unit of Measure Conversion program (P41002) or the Standard Unit of Measure Conversion program (P41003) to setup the necessary conversion factor(s).
UOM Conversion EA to MO Unsuccessful Warning
ER Details:
Form P4112_W4112A
Control Id 1
Control Title Grid
Event Row is Exit & Changed - Asynch
Line No 106
BSFN Details:
Source File b4000520.c
Source Line 642
Error ID 085D
Note: You can get this information in your clicking a small yellow triangle in the right side of error box.
Error 2: 124K - Number of Units Invalid
CAUSE . . . . The number of units entered cannot be zero if the unit of measure is not blank. Alpha characters are the equivalent of zero in a numeric field.
RESOLUTION. . Enter a non-zero unit or blank out the unit of measure.
Number of Units Invalid Warning
ER Details:
Form P4112_W4112A
Control Id 1
Control Title Grid
Event Row is Exit & Changed - Asynch
Line No 106
BSFN Details:
Source File b0900049.c
Source Line 7156
Error ID 124K
when there is no correlation between EA and MO for the item for this transaction. And how to overcome the error 'Number of Units Invalid' even when there is sufficient inventory to issue for the item?
and quantity available,
Solution