E1: 31B: R31B65AZ1I Creates Additive Operation With Incorrect UOM

(Doc ID 2391778.1)

Last updated on MAY 15, 2018

Applies to:

JD Edwards EnterpriseOne Blend Management - Version 9.2 and later
Information in this document applies to any platform.

Symptoms

E1 9.2 / R31B65AZ1I Blend Inbound Processor

When creating an Additive operation with interop, R31B65AZ1I, and entering the additive with a UOM that is not the Primary or Production UOM (but with a conversion to the primary
UOM) , the operation is created with the correct Z1 quantity value but with the Additive Bill of Material UOM.
The R31B65AZ1I indicates the operation is created successfully without error. However, there is a "UOM conversion" error in the Work Center.

For example, the P31B65Z1 additive item quantity is 100 and UOM is GM- The operation is created with the additive item quantity 100 and UOM LB (Additive item Production UOM).

If the same data is entered manually (P31B94), a hard UOM conversion error is generated and the operation cannot be entered.

Changes

 

Cause

Sign In with your My Oracle Support account

Don't have a My Oracle Support account? Click to get started

My Oracle Support provides customers with access to over a
Million Knowledge Articles and hundreds of Community platforms