E1: 31B and 40G: Spray Item Error Not Cleared After Corrected

(Doc ID 2393053.1)

Last updated on APRIL 30, 2018

Applies to:

JD Edwards EnterpriseOne Grower Management - Version 9.2 to 9.2 [Release 9.2]
JD Edwards EnterpriseOne Blend Management - Version 9.2 to 9.2 [Release 9.2]
Information in this document applies to any platform.

Symptoms

E1 9.2 / P40G30 Grower Operation entry

"invalid Spray Item" error is not cleared after correcting the error.

When creating a Spray Operation (base code SPRAY) on Farming Activities (P31B94 / P40G30), if, in the Spray Info form, the Item Number field is left blank and Save and Close is clicked, the "invalid Spray Item" error is correctly displayed.  
However, if a valid spray item is then entered and Save and Close clicked, the error is not cleared.  The application must be exited (click CANCEL) and the operation must be entered again.


ERROR
-----------------------
Invalid Spray Item- CAUSE: The spray item number and/or branch plant is blank or does not exist in the spray master (P40G041).  Error id 850B

Changes

 

Cause