Symptoms
The system is generating the below error while user is entering the cycle count quantity. The error occurs though the branch plant is a non-warehouse one.
ERROR
-----------------------
Unit of Measure Structure Not Determined
Error ID : 3485
CAUSE . . . . The Unit of Measure structure for this item/ unit of measure can not be determined.
RESOLUTION. . Verify that a structure for this item/ unit of measure is defined in the U/M Conversion
Information program, verify the Item Profile and U/M Definition by Group/Item information is defined.
STEPS
-----------------------
1. Select an item for count in a Branch plant whose Warehouse Control flag is turned off in Branch Plant Constants(P41001)
2. R41410A Print the cycle count
3. P4141 add quantities for the items Error is displayed
Changes
Cause