E1: 47: Flat File Conversion Fails if Fields Are Formatted With Two Double Quotes With No Space ("")
(Doc ID 2745855.1)
Last updated on JANUARY 21, 2021
Applies to:
JD Edwards EnterpriseOne EDI - Version 9.2 and laterInformation in this document applies to any platform.
Symptoms
When attempting to run Inbound Flat File Conversion (R47002C) for the first time with EDI 850 Inbound, the program crashes and partially updates the EDI tables. The EDI Purchase Order Header - Inbound (F47011) record is written but the system fails to write an EDI Purchase Order Detail - Inbound (F47012) record.
The following error message appears in the JDE.LOG
- JDB3400009 - Failed to perform Insert for F47012
The 11th field in the EDI Purchase Order Header - Inbound (F47011) record which is the Successfully Processed (EDSP) flag is populated with a single quote (“) instead of a blank.
The corresponding input field in the flat file for this was two double quotes with no space (“”).
Changes
Cause
To view full details, sign in with your My Oracle Support account. |
|
Don't have a My Oracle Support account? Click to get started! |
In this Document
Symptoms |
Changes |
Cause |
Solution |
References |