E1:30: Manufacturing Constants (P3009) Checked for On-Line BOM Validation - Still Allowing Recursive Items on BOM To Be Added (Doc ID 2754664.1)

Last updated on FEBRUARY 23, 2021

Applies to:

JD Edwards EnterpriseOne Product Data Management - Version 9.2 and later
Information in this document applies to any platform.

Symptoms

With the Manufacturing Constants (P3009) being checked for On-Line BOM Validation, The P3002 Bill of Materials is allowing a recursive Item to be added without an error and/or warning.

The Bill of Material Structure Analysis (R30601) report does find recursive bill errors on an Item in a Branch even though P3009 Manufacturing Constants On-Line BOM Validation is checked ON for that Branch Plant.

Steps:

  1.  Make sure the P3009 Mfg Constants is checked for Checking On-Line bill Validation
  2.  Setup a BOM Parent Item (0130) with a purchased component (0140)
  3.  Now add a new BOM with the Component (0140) being the Parent item Number and Component (0130) being the Parent Item Number (This is Recursive)
  4.  However,  the system allows the BOM to be entered with No Errors
     
     
     

Changes

 

Cause

To view full details, sign in with your My Oracle Support account.