E1: 31: Unable to Generate Serial Numbers in Serial Number Revisions - P3105 Greater than the Work Order Quantity Due to Error ID 4717 'Number of LSNs exceeds quantity required'
(Doc ID 2809008.1)
Last updated on OCTOBER 04, 2022
Applies to:
JD Edwards EnterpriseOne Shop Floor Control - Version 9.2 and laterInformation in this document applies to any platform.
Symptoms
Currently in Serial Number Revisions (P3105), if the user attempts entering a serial number quantity greater than the Work Order quantity, the system will generate the following error:
Number of LSNs exceeds quantity required
Error ID 4717
However, after reporting parent scrap (IS, P31114), the user will not be able to return to Serial Number Revisions and generate a new Serial Number so that it can be later used for a Work Order completion.
The request is to add functionality to the P3105 where Serial Number could be generated for a quantity greater than the order quantity. Below are suggestions to allow this:
1. The system could check Work Order parent scrap quantity when determining whether to allow for additional serial numbers to be generated via P3105.
2. Add a processing option to Assign Serial Numbers (P3105) to bypass error ID 4717.
3. Add a processing option to make error ID 4717 a warning if generating more serial numbers than then Work Order quantity.
Cause
To view full details, sign in with your My Oracle Support account. |
|
Don't have a My Oracle Support account? Click to get started! |
In this Document
Symptoms |
Cause |
Solution |
References |