Symptoms

The Decimals are not displayed correctly in the QA Test results application P31B25 (Quality History Inquiry). The QA Quality History Inquiry does NOT respecting the decimal format of the original inputs, unlike other areas of the system. For example, following blending, the P31B25 incorrectly displays a pH test result of 338 for the after lot instead of 3.38 as expected.

STEPS TO REPLICATE:

  1. Identify two blend lots (vessels) without QA test results.
  2. Perform a QA operation on the first vessel, adding several Test IDs and Results with a weighted average (AVERG) blend rule.
  3. Perform a QA operation on the second vessel, adding the same Test IDs and different Results with a weighted average (AVERG) blend rule and also add a unique Test ID and Results not applied to the first vessel.
  4. Perform a T2T operation, moving a quantity of wine from each vessel to a third, empty vessel.
  5. Run P31B25 Quality History Inquiry on the new blend lot in the third vessel.
  6. P31B25 displays incorrect Results for the weighted average Test IDs, with decimals not respected, but the unique Test ID displays with decimals as entered in the second vessel. 

Changes

 