My Oracle Support Banner

E1: 13: Changing a PM Schedule (P1207) Results in Negative Meter Interval Display Value (Doc ID 2822898.1)

Last updated on NOVEMBER 19, 2021

Applies to:

JD Edwards EnterpriseOne Capital Asset Management - Version 9.2 and later
Information in this document applies to any platform.

Symptoms

After making a change to a meter-based Equipment Preventive Maintenance Schedule (P1207, form W1207B), the system will return to the Work with PM Schedule form (W1207A) with the Interval Service value displayed as a negative value.

STEPS

The issue can be reproduced at will with the following steps:
1. Inquire on a meter-based PM Schedule (P1207) that uses Service Hours Schedule Interval.
2. Select the record to access the W1207B form.
3. Change the Last Completed Hours and click save.
4. Upon returning to the Work with Equipment PM Schedule form (W1207A), notice that the Service Hours display as a negative value (as it is stored in the F1207 table).
5. Click on the find button; the system refreshes and displays Service Hours correctly.

Changes

 

Cause

To view full details, sign in with your My Oracle Support account.