My Oracle Support Banner

E1: 34: Planning Console (P34X200) after clicking Implement Plan gives Error 018A ""value" not found in User Defined Code 00 W1 (or 00 W2, or 00 W3)" (Doc ID 2886127.1)

Last updated on AUGUST 07, 2023

Applies to:

JD Edwards EnterpriseOne Requirements Planning - Version 9.2 and later
Information in this document applies to any platform.

Symptoms

The Planning Console P34X250 gives Error 018A after clicking on Implement Plan button.

 

The details of the error message indicate that it is comparing values from F4801.WR01 to UDC 00/W1 and F4801.WR02 to UDC 00/W2 and F4801.WR03 to UDC 00/W3.

Manufacturing Work Order Entry (P48013) has Processing Options that allow the Cat Codes to be directed to alternate UDC tables for Cat 01, Cat 02, and Cat 03 (see Tab 4, Options 4, 5, and 6). The P34X250 appears to not have the same processing options. It is common practice to point the Cat 01 and Cat 02 as follows:

F4801.WR01=41/S1
F4801.WR02=41/P4

This results in Values on the WO Header (F4801) being validated against the wrong UDC table and the Error 018A being triggered.

 

Changes

 

Cause

To view full details, sign in with your My Oracle Support account.