E1: 31: BSFN: "'struct' type redefinition" Error (C2011) Generated When Both B3104175 and B3104170 are Included in NER
(Doc ID 2930869.1)
Last updated on FEBRUARY 27, 2023
Applies to:
JD Edwards EnterpriseOne Tools - Version 9.2 and laterJD Edwards EnterpriseOne Shop Floor Control - Version 9.2 and later
Information in this document applies to any platform.
Symptoms
A simple Named Event Rule (NER) cannot call business functions B3104175 and B3104170 during the busbuild process.
The Build Output or buildlog.txt includes the following:
ERROR
-----------------------
N5731803.c
D:\E920\DV920\include64\b3104175.h(69): error C2011: 'tagDSD3104170F4801T': 'struct' type redefinition
D:\E920\DV920\include64\b3104170.h(85): note: see declaration of 'tagDSD3104170F4801T'
Steps:
1. Add NER which includes B3104175 and B3104170 to a project in OMW (signed into fat/dev client)
2. Highlight NER in project and select Design icon in middle of screen
3. Go to Design Tools tab and select Build Business Function
4. Review the Build Output results (buildlog.txt can also be found under the C:\E920\DV920\work directory)
Changes
Updating to Tools Releases 9.2.6.5 or above has not been confirmed as the trigger, but the issue has been confirmed/duplicated in Tools Releases 9.2.6.5 and 9.2.7.
Cause
To view full details, sign in with your My Oracle Support account. |
|
Don't have a My Oracle Support account? Click to get started! |
In this Document
Symptoms |
Changes |
Cause |
Solution |
References |