E1: 31: 37: Test Results Revisions - P3711 Triggers Error ID 001H - 'No Grid Record Selected' Due to Incorrect Version Passed from WO Completion - P31114 for Process Items
(Doc ID 3055099.1)
Last updated on OCTOBER 22, 2024
Applies to:
JD Edwards EnterpriseOne Shop Floor Control - Version 9.2 and laterInformation in this document applies to any platform.
Symptoms
When performing a completion for a process item with quality profile enabled, the wrong version is passed from P31114 Work Order Completions to P3711 Test Results Revisions and is causing screen error 001H (No Grid Record Selected).
Steps:
- In IV set a version of P31114 | BUG31114 to call a specific version of P3711 | BUG3711. P31115 is versionless.
- Use P31114 | BUG31114 to perform a completion for a process item set with Quality Preference Profile in P40318
- From P31114, P31115 is called, save the info. Then P3711 is called with version “default”.
If pressing OK, the error appears on screen: error ID 001H - 'No Grid Record Selected'.
Note that when pressing Cancel in P3711, it opens again with the correct version this time, | BUG3711.
Changes
ESU JN20829.
Cause
To view full details, sign in with your My Oracle Support account. |
|
Don't have a My Oracle Support account? Click to get started! |
In this Document
Symptoms |
Changes |
Cause |
Solution |
References |