E1: 13: P1311 Condition-Based Alert Event Time 00:00:xx Results in Invalid Event Time Error 1A59
(Doc ID 3079983.1)
Last updated on APRIL 03, 2025
Applies to:
JD Edwards EnterpriseOne Capital Asset Management - Version 9.2 and laterJD Edwards EnterpriseOne Condition Based Maintenance - Version 9.2 and later
Information in this document applies to any platform.
Symptoms
The P1311 Condition-Based Alerts Revisions program allows adding a record with the Event Time of 00:00:xx, but cannot edit the record later without generating a hard error. When edit or update the Condition Based Maintenance (CBM) record with time 00:00 in P3111, get a hard system error, Invalid Event Time Warning, Error ID 1A59. This is an invalid error, as Event Time 00:00 can be saved to the record, initially.
.
Steps:
- G1311/P1701 Equipment Master - Add or Select Asset Record for Condition Based Maintenance tracking.
- G13CBM10/P1310 Condition-Based Alerts Workbench - Add a Condition-Based Alert.
- P1311 Condition-Based Alerts Revisions - Enter Event Description, Alert Level, and Event Date. Enter Event Time as 00:00:xx. Optionally, populate Equipment or Asset Number (ASII). Save Changes.
- P1310 - Reinquire and validate that record was saved with no hard errors. Select record for update in P1311.
- P1311 - Add text or other update and save changes.
- System Generates Invalid Event Time hard error, Error ID 1A59.
Cause
To view full details, sign in with your My Oracle Support account. |
|
Don't have a My Oracle Support account? Click to get started! |