Oracle Warehouse Builder 11.2 Control Center Service Fails to Start with ORA-29532 And ORA-01017 (Doc ID 1387816.1)

Last updated on NOVEMBER 25, 2015

Applies to:

Oracle Warehouse Builder - Version 11.2.0.1 and later
Information in this document applies to any platform.
***Checked for relevance on 28-May-2013***

Symptoms

The OWB 11.2 Control Center Service fails to start.

Starting it from SQLPlus using the start_service.sql scripts reports the following:

Diagnostics:
service startup failure using command "/u01/app/oracle/product/tst_ora11/owb/bin/unix/run_service.sh -manual 1 /u01/app/oracle/product/tst_ora11 OWBSYS host:1521:orcl" reason:

ORA-29532: Java call terminated by uncaught Java exception: java.io.IOException: service early exit: code=255 : err=2011/12/14-1

6:36:48-EST [742808B3][] java.sql.SQLException: ORA-01017: invalid username/password; logon denied

at oracle.jdbc.driver.T2CConnection.checkError(T2CConnection.java:759)
at oracle.jdbc.driver.T2CConnection.logon(T2CConnection.java:414)
at oracle.jdbc.driver.PhysicalConnection.<init>(PhysicalConnection.java:536)
at oracle.jdbc.driver.T2CConnection.<init>(T2CConnection.java:16
please invoke [owbhome]/owb/rtp/sql/service_doctor.sql for more information

PL/SQL procedure successfully completed.




Cause

Sign In with your My Oracle Support account

Don't have a My Oracle Support account? Click to get started

My Oracle Support provides customers with access to over a
Million Knowledge Articles and hundreds of Community platforms