OGG DataPump Abends With OGG-01349 At Restart

(Doc ID 1564716.1)

Last updated on JANUARY 12, 2017

Applies to:

Oracle GoldenGate - Version and later
IBM z/OS on System z
A working OGG on z/OS with a fully working and functional OGG did fail if data pump jobs are stopped and restarted


After stopping and restarting data pump job it errors out with

2013-06-07 10:03:00 ERROR OGG-01349 Could not convert ASCII data to EBCDIC.
2013-06-07 10:03:00 ERROR OGG-01668 PROCESS ABENDING.

after restarting data pump jobs the trail files are correctly created.


 Added TRAILCHARSETASCII and SOURCEDB parameter in extract data pump parameter file