My Oracle Support Banner

In Exalogic Physical Rack With LAG (Link Aggregation) Setup, No VNICs Are Shown On IB NM2-GW Switches After Upgrading IB NM2-GW Switches During PSU Upgrade (Doc ID 2281490.1)

Last updated on NOVEMBER 14, 2022

Applies to:

Oracle Exalogic Elastic Cloud Software - Version 2.0.6.2.0 to 2.0.6.2.170418
Oracle Exalogic Elastic Cloud Software - Version 2.0.4.0.4 to 2.0.4.0.4
Linux x86-64

Symptoms

In Exalogic Physical rack with Link Aggregation setup on IB switches for EOIB network, After upgrading the NM2-GW switch firmware to 2.2.4-3 as part of April 2017 PSU upgrade , There are no vNics on the switches and EOIB connectivity to the compute nodes is lost. At the time of the issue, SSH and Pings to Compute Nodes does not work over EOIB network.

On Compute nodes we will see that the EOIB bond interface will have all zeroes for MAC address and  ethxxx_1.abc interfaces will be not seen in ifconfig output on compute nodes

Note that this is not specific to upgrading the firmware version to 2.2.4-3. This can happen on previous IB firmware versions as well.

Changes

Upgraded IB switch firmware version to 2.2.4-3.

Cause

To view full details, sign in with your My Oracle Support account.

Don't have a My Oracle Support account? Click to get started!


In this Document
Symptoms
Changes
Cause
Solution
References


My Oracle Support provides customers with access to over a million knowledge articles and a vibrant support community of peers and Oracle experts.