My Oracle Support Banner

FRM- 93552 : Cannot Connect to runtime Process In FMW 12.2.1.3.0 On Windows - MSVCP100.dll is Missing. (Doc ID 2337361.1)

Last updated on MAY 03, 2023

Applies to:

Oracle Forms - Version 12.2.1.3.0 to 12.2.1.3.0 [Release 12.2]
Information in this document applies to any platform.

Symptoms

New installation of Forms and Reports 12.2.1.3.0 on Windows.

Running the test form results in the following error:

FRM- 93552 : Cannot Connect to runtime Process

The formsapp-diagnostic.log shows:


[2017-11-30T16:56:38.444-05:00] [WLS_FORMS] [ERROR] [FRM-93552] [oracle.forms.servlet] [tid: 23] [Id: <none>] [ecid: 00000000000000000000000000000,0] [APP: formsapp] [partition-name: DOMAIN] [tenant-name: TENANT] [FORMS_SESSION_ID: WLS_FORMS.formsapp.1] [SRC_CLASS: oracle.forms.servlet.BaseServlet] [SRC_METHOD: logConnectionException] cannot connect to runtime process: Newly created runtime process has terminated abnormally.


Executing the frmweb.exe executable from the command line shows that MSVCP100.dll is missing.

 

Changes

New installation of Forms and Reports 12.2.1.3.0.

Cause

To view full details, sign in with your My Oracle Support account.