12.2.1.3.0 TEST.FMX on IBM AIX fails with FRM-93552/FRM-93546 rtld: 0712-00 libclntsh.so(), but a runtime definition of the symbol was not found
(Doc ID 2461264.1)
Last updated on MAY 03, 2023
Applies to:
Oracle Forms - Version 12.2.1.3.0 and laterIBM AIX on POWER Systems (64-bit)
Symptoms
Running Test.fmx on new install of Oracle Forms 12.2.1.3.0 on IBM AIX, It fails with the following errors:
FRM-93552 cannot connect to runtime process: Newly created runtime process has terminated abnormally.
FRM-93546 external message from runtime process: exec(): 0509-036 Cannot load program frmweb because of the following errors:
FRM-93546 external message from runtime process: rtld: 0712-001 Symbol CreateIoCompletionPort was referenced
FRM-93546 external message from runtime process: from module /Oracle_Home/lib/libclntsh.so(), but a runtime definition
FRM-93546 external message from runtime process: of the symbol was not found.
FRM-93546 external message from runtime process: exec(): 0509-036 Cannot load program frmweb because of the following errors:
FRM-93546 external message from runtime process: rtld: 0712-001 Symbol CreateIoCompletionPort was referenced
FRM-93546 external message from runtime process: from module /Oracle_Home/lib/libclntsh.so(), but a runtime definition
FRM-93546 external message from runtime process: of the symbol was not found.
Changes
New install of FMW Oracle Forms 12.2.1.3.0 on IBM AIX.
Cause