"ODI-30048" Encountered when Using the ODI 12c OdiExportObject Tool to Export a Sub-Model
(Doc ID 2529198.1)
Last updated on APRIL 19, 2021
Applies to:
Oracle Data Integrator - Version 12.1.2.0.0 to 12.2.1.4.0 [Release 12c]Information in this document applies to any platform.
Symptoms
The Oracle Data Integrator (ODI) 12c OdiExportObject tool fails to export a Sub-Model, and following error message is observed in the corresponding Session:
ODI-30048: Unable to find the object with type SnpSubModel and identifier
For reproducing the behavior:
- Create a Model.
- Create a Sub-Model inside this Model.
- Create a Package, and implement the OdiExportObject command with "-CLASS_NAME=SnpSubModel" property:
OdiExportObject "-CLASS_NAME=SnpSubModel" "-I_OBJECT=<GUID OF THE SUB-MODEL>" ...
- Run the Package, and observe the ODI-30048 received.
- Use regular export (or smart export) of the same Sub-Model, and observe the export succeeds.
Cause
To view full details, sign in with your My Oracle Support account. |
|
Don't have a My Oracle Support account? Click to get started! |
In this Document
Symptoms |
Cause |
Solution |
References |