My Oracle Support Banner

Running Any Command from ORACLE_HOME/ohs/bin Fails with the Error "symbol lookup error" and "undefined symbol: __intel_new_proc_init" (Doc ID 2692496.1)

Last updated on JULY 24, 2023

Applies to:

Oracle HTTP Server - Version 12.2.1.4.0 and later
Information in this document applies to any platform.

Symptoms

When trying to run "htpasswd" command, for storing usernames and password for basic authentication, it fails with the below errors:

Running any command present under ORACLE_HOME/ohs/bin fails with the same errors.

Issue can be reproduced at will using the below steps:

1. Open bash_profile file present under user's home directory
vi .bash_profile
2. Set env variables as below:
ORACLE_HOME=<PATH_TO_ORACLE_HOME>
export ORACLE_HOME
LD_LIBRARY_PATH=$ORACLE_HOME/lib:$ORACLE_HOME/ohs/lib
export LD_LIBRARY_PATH
3. Navigate to ORACLE_HOME/ohs/bin
4. Run any command in ORACLE_HOME/ohs/bin and it fails with the above mentioned errors.

Changes

 