Extract Abended With Error OGG-25103 on GPFS Filesystem
(Doc ID 2818231.1)
Last updated on APRIL 17, 2023
Applies to:
Oracle GoldenGate - Version 19.1.0.0.4 and laterInformation in this document applies to any platform.
Symptoms
When 2 export dump files are imported at same time into datapump on the source side, extract abends with below error
--> ERROR OGG-25103 Oracle GoldenGate Capture for Oracle, <extract>.prm: ERROR: write() system call: bytes-to-do: 1636964 bytes-done: -1 fd: 28 error5 (I/O error)
Below is sequence to reproduce issue
A. start extract
B. Multi session IMPDP
Session A: Executing impdp
Session B: Executing impdp
C. OGG error occurred
ERROR OGG-25103 Oracle GoldenGate Capture for Oracle, <extract>.prm: ERROR: write() system call: bytes-to-do: 1636964 bytes-done: -1 fd: 27 error5 (I/O error).
ERROR OGG-01668 Oracle GoldenGate Capture for Oracle, <extract>.prm: PROCESS ABENDING.
D. Extract abended with ERROR OGG-25103 but all GGSCI interfaces are displayed in RUNNING state
Cause
To view full details, sign in with your My Oracle Support account. |
|
Don't have a My Oracle Support account? Click to get started! |
In this Document
Symptoms |
Cause |
Solution |