My Oracle Support Banner

Extract Abended With Error OGG-25103 on GPFS Filesystem (Doc ID 2818231.1)

Last updated on APRIL 17, 2023

Applies to:

Oracle GoldenGate - Version 19.1.0.0.4 and later
Information in this document applies to any platform.

Symptoms

When 2 export dump files are imported at same time into datapump on the source side, extract abends with below error

--> ERROR OGG-25103 Oracle GoldenGate Capture for Oracle, <extract>.prm: ERROR: write() system call: bytes-to-do: 1636964 bytes-done: -1 fd: 28 error5 (I/O error)

 Below is sequence to reproduce issue
A. start extract

B. Multi session IMPDP
Session A: Executing impdp
Session B: Executing impdp

C. OGG error occurred
ERROR OGG-25103 Oracle GoldenGate Capture for Oracle, <extract>.prm: ERROR: write() system call: bytes-to-do: 1636964 bytes-done: -1 fd: 27 error5 (I/O error).
ERROR OGG-01668 Oracle GoldenGate Capture for Oracle, <extract>.prm: PROCESS ABENDING.

D. Extract abended with ERROR OGG-25103 but all GGSCI interfaces are displayed in RUNNING state