PROBLEM DESCRIPTION:

Two times in the last weeks, a tmboot of the secondary node of an MP application failed in production.

The error was:

exec /home/inet/tuxnds/bin/SRVINTERFACES -A -r -e /home/inet/dominio2/estadis/tuxnds/SRVINTERFACES.trz -o
/home/inet/tuxnds/logs/SRVINTERFACES.out -- -d /home/inet/tuxnds/logs -r NDS :
        on dom_INET2 ->
CMDTUX_CAT:854: ERROR: tmloadcf error on dom_INET2 tmloadcf output:
        SICACHEENTRIESMAX="500" MAXQUEUELEN=0
                                                             ^
                                            invalid value

CMDTUX_CAT:5206: WARN: The MAXQUEUELEN parameter must be >= 1 and <= 1000

CMDTUX_CAT:867: ERROR: /usr/tuxedo/inet2/bin/tmloadcf: Above errors found during syntax checking
CMDTUX_CAT:814: ERROR: Cannot propagate TUXCONFIG file

tmboot: WARN: No BBL available on site dom_INET2.    Will not attempt to boot server processes on that site.



As you can see, tmloadcf complains about MAXQUEULEN=0.  However, this parameter is not set at the ubbconfig and was not set by any other means (tmconfig, etc).