E2B Generation Error 402000611 Occurs If Case Contains Female Patient
(Doc ID 1298576.1)
Last updated on JULY 13, 2023
Applies to:
Oracle Life Sciences Argus Interchange - Version 5.1.1 and laterInformation in this document applies to any platform.
Symptoms
When attempting to generate an E2B report, generation error 402000611 can occur if Parent is female:
Steps to Repeat:
1. Bookin a case with just the required fields during bookin.
2. Open the case.
3. General Tab > Enter reporter last name.
4. Patient Tab > Enter patient initials
5. Parent tab > Enter gender as female
6. Analysis > Enter Narrative.
7. Save case.
8. Preview Draft of an E2B report.
9. E2B report does not appear, instead Error No: 402000611 is displayed:
Error No: 402000611 Description: Case TEST2 is missing mandatory optional E2b
information. The following elements are MANDATORY OPTIONAL elements and one
of them must contain data: PATIENTINITIAL, PATIENTGPMEDICALRECORDNUMB,
PATIENTSPECIALISTRECORDNUMB, PATIENTHOSPITALRECORDNUMB,
PATIENTINVESTIGATIONNUMB, PATIENTBIRTHDATE, PATIENTONSETAGE,
PATIENTONSETAGEUNIT, GESTATIONPERIOD, PATIENTAGEGROUP, PATIENTSEX. Stored
procedure: GENERATE_SAFETYREPORT
information. The following elements are MANDATORY OPTIONAL elements and one
of them must contain data: PATIENTINITIAL, PATIENTGPMEDICALRECORDNUMB,
PATIENTSPECIALISTRECORDNUMB, PATIENTHOSPITALRECORDNUMB,
PATIENTINVESTIGATIONNUMB, PATIENTBIRTHDATE, PATIENTONSETAGE,
PATIENTONSETAGEUNIT, GESTATIONPERIOD, PATIENTAGEGROUP, PATIENTSEX. Stored
procedure: GENERATE_SAFETYREPORT
Changes
Cause
To view full details, sign in with your My Oracle Support account. |
|
Don't have a My Oracle Support account? Click to get started! |
In this Document
Symptoms |
Changes |
Cause |
Solution |
References |