Symptoms
=== ODM Issue Clarification ===
We have run several OU MDM database schema upgrade scripts containing the genAuditTrgs.wsf script. This script seems to work fine except that in several instances it generates the following error:
genAuditTrgs.wsf(1065, 10) ADODB.Stream: Write to file failed.
This occurred when applying the following patches to upgrade our OU MDM database:
- script to upgrade EIP db from 1.6.0 to 1.6.1 (v22317 upgradeEIP.cmd script)
- script to upgrade MDM db from 1.6.0 to 1.6.1 (v22011 updateMDM.cmd script)
- patch 11711357 (upgrade to 1.6.1.1)
We investigated and found that these patches did not introduce any metadata changes so we carried on. Further patches to upgrade the database to 1.6.1.2 (patch 11711361) and then to 1.6.1.3 (pat. 11818855) contained also a genAuditTrgs.wsf script but in those 2 patches, it worked fine without generating any errors.
Cause
To view full details, sign in with your My Oracle Support account. |
|