OCSB 3.1.0:HLR Query Problem Caused By SSU (Doc ID 1324557.1)

Last updated on OCTOBER 10, 2016

Applies to:

Oracle Communications Service Broker - Version 3.1.0 and later
Information in this document applies to any platform.

Symptoms

Problem with HLR query - sometimes the ssu does not send the ATI response to imscfts, but writes an error log:


[2011-05-05 19:26:39,989][[ACTIVE] ExecuteThread: '1' for queue: 'weblogic.kernel.Default (self-tuning)'][SID:919646][app=ssuserver][ERROR][com.convergin.common.servlet.sib.Sip2Sccp.getProtocolStack():-1][No destination found for event !!! ]
[2011-05-05 19:26:39,989][[ACTIVE] ExecuteThread: '1' for queue: 'weblogic.kernel.Default (self-tuning)'][Trd:23][app=ssuserver][ERROR][com.convergin.common.bsw.network.channelmanager.ChannelManager.sendToApplication():-1][SsuServerSession.onMessage failed, SccpGeneralException [Event does not contain fields needed for dispatching. Null destination.]]


So the imscfts will send a map_timeout to application after 10 sec.


[2011-05-05 19:26:49,905][[ACTIVE] ExecuteThread: '0' for queue: 'weblogic.kernel.Default (self-tuning)'][SID:212833][app=imscftsCa][ERROR][com.convergin.common.ss7.applicationpart.event.component.ind.AppLocalCancelIndEvent.process():-1][Local cancel received - timeout]