IMD VEE exceptions fail to create To Do in Meter Data Management (Doc ID 1364413.1)

Last updated on NOVEMBER 16, 2015

Applies to:

Oracle Utilities Meter Data Management - Version: 2.0.1 and later   [Release: 2.0 and later ]
Information in this document applies to any platform.

Symptoms

When IMDs fail during VEE and the underlying BO transitions to the exception state, a To Do should be created - but it does not, and the system throws a 'message parm type is missing error'


USER001 - 355093-64914-1 2011-09-06 17:38:41,413 [[ACTIVE] ExecuteThread: '13' for queue: 'weblogic.kernel.Default (self-tuning)'] ERROR (support.schema.MessageRepository) Detail of Schema input error: Input request is missing required node 'Message Parm Type' (xpath=/messageParameters/messageParametersList[1]/messageParameterType).
CON21005 - 355093-64914-1 2011-09-06 17:38:41,419 [[ACTIVE] ExecuteThread: '13' for queue: 'weblogic.kernel.Default (self-tuning)'] INFO (support.context.FrameworkSession) (Server Message)
Category: 11001
Number: 1853
Call Sequence:
Program Name: PerformVEEAlgComp_Impl
Text: Message Parm Type is missing.
Description:
Table: null
Field: null

Cause

Sign In with your My Oracle Support account

Don't have a My Oracle Support account? Click to get started

My Oracle Support provides customers with access to over a
Million Knowledge Articles and hundreds of Community platforms