ExecuteReaderException when Accessing MDM Clip when Data Access is Secured (Doc ID 1439385.1)

Last updated on AUGUST 22, 2016

Applies to:

Oracle Utilities Meter Data Management - Version 1.6.1.4 and later
Information in this document applies to any platform.

Symptoms

In EIP (Energy Information Platform) when a user that has restricted access to the data sources attempts to access the service point table an error occurs,

ExecuteReaderException: ORA0933 SQL command not properly ended.


The issue can be reproduced at will with the following steps:

  1. Configure the security data access restricted based on operating company
  2. Add a data access key for a group for one operating company
  3. Add a user to this group
  4. Try to access the MDM clip from the account link and you see this error.


Related Errors in EIP

Account Clips - Meter Data Management:

Error (0x90430001): ExecuteReaderException: ORA-00904: "LSMDMTRDATAREAD"."UIDMTRDATACHANNEL": invalid identifier

MDM Usage Event/Exception Result:

Error (0x90430001): ExecuteReaderException: ORA-00904: "PM"."OPCOCODE": invalid identifier

Cause

Sign In with your My Oracle Support account

Don't have a My Oracle Support account? Click to get started

My Oracle Support provides customers with access to over a
Million Knowledge Articles and hundreds of Community platforms