My Oracle Support Banner

Data Synchronization process does not initiate automatically when scheduling Control Analysis (Doc ID 1487709.1)

Last updated on SEPTEMBER 11, 2020

Applies to:

Oracle Application Access Controls Governor - Version 8.6 and later
Information in this document applies to any platform.

Symptoms

Oracle Application Access Controls Governor (AACG) executes models and controls that define conflicts among duties that can be assigned in a company’s applications, and identify users who have conflicting access to those duties.
On AACG version 8.6.3:

When scheduling a Control Analysis, there is a check box to synchronize data before the Conflict Analysis is run.
However, even after checking this box only the Conflict Analysis process is run job and the data synchronizing does not occur.
  
Expected Behaviour
----------------------------
The data synchronization (ETL) process should run before the conflict analysis (CA)

Actual Behaviour
----------------------------
The data synchronization (ETL) process does not run prior to the conflict analysis process.

Steps to reproduce
--------------------------
1. Log in to AACG
2. Select Control(s)
3. Click on Action > Schedule to schedule the Conflict Analysis.
4. Ensure that the "Synchronize Datasource" check box is checked.
5. Click on Schedule button
6. Go to Jobs and Scheduling > Manage Jobs screen and see that only the Conflict Analysis is run and the data synchronization (ETL) process is not run.

-- Business Impact
The issue has the following business impact:
Due to this issue, users have to manually run ETL before running Conflict Analysis.

Cause

To view full details, sign in with your My Oracle Support account.

Don't have a My Oracle Support account? Click to get started!


In this Document
Symptoms
Cause
Solution
References


My Oracle Support provides customers with access to over a million knowledge articles and a vibrant support community of peers and Oracle experts.