[Objectel] - Error When Resolving The Circuit Path

(Doc ID 1503367.1)

Last updated on AUGUST 10, 2016

Applies to:

Oracle Communications Objectel - Version 2.10.3 and later
Information in this document applies to any platform.

Symptoms

The issue is reproducible in both Customer's and Oracle's sample metadata.

The steps to reproduce the issue are:

#######Oracle's sample metadata#######

1- Deploy Oracle's sample

2- Create 4 FEs (FE1, FE2, FE_X, FE3) with 2 DS1 ports each one.

3- Create a TDM Facility between FE1 and FE2:
  a. Source FE1 and Target FE2
  b. Technology TDM - Signal DS1

4- Create a TDM Facility between FE_X and FE2:
  a. Source FE_X and Target FE2
  b. Technology TDM - Signal DS1

5- Create a TDM Facility between FE3 and FE_X:
  a. Source FE3 and Target FE_X
  b. Technology TDM - Signal DS1

6- Starts the creation of a Circuit (Technology TDM - Signal DS1) between FE1 and FE3

7- In the Functional Gap Resolution:
  a. Select both FEs and select Get Path With Mininum Hops
  b. Set Max Number of Hops =3 and Press Find Button
  c. Assign the Facility created in step 3
  d. Assign the Facility created in step 5

Result: Objectel Client will crash.

The problem is related when the Exit Node does not belong to the terminating points from the next segment.