ORA-01422 Error At Follow-up E2B Import
(Doc ID 1517005.1)
Last updated on JULY 13, 2023
Applies to:
Oracle Life Sciences Argus Safety Japan - Version 7.0.0 and laterInformation in this document applies to any platform.
Goal
This note is describing how to workaround the following issue of the BUG:13073685
on Argus Safety versions before the BUG:13073685 is fixed.
When a follow-up E2B is imported to a case that has pregnancy information in both patient and parent,
an error is shown at [Accept E2B] operation.
Error Message:
--------------
Fatal Error: ORA-01422: exact fetch returns more than requested number of rows. Failed to update record. Module : CREATE_CASE_PREGNANCY [3]
The symptom is occurs when
--The case_pregnancy table has two records.
--The E2B follow-up file contains updates for patient or parent.
Solution